Next we will add Spot highlighted connector views to our connectors these display wire colours, cavity location, multipoint crimps. To enable the Generated Views option for a drawing Click the Edit Task icon under the Drawing selection screen (Fig 50.1) and setting Connector to Generated and WireNames to Always (Fig 50.2) and Submit to complete.
Fig 1, Shows the Details of connector X-003 on the Harness drawing with the spot Highlighter set, All cavities now show the wire colour inserted in them along with a leader line displaying the circuit/Wire its connected to i.e, Cavity 5, Brown W004.
Fig 1 Connector X-003 Generated view with wire colours highlighted
Leader labels can be moved by right clicking the spot highlight control node and selecting Move Wire Leads (Fig 2) this can be useful for grouping wire colours together shown in Fig 3, to save the changes right click on the control node and select Save.
Fig 2 Options menu for spot highlighter Fig 3 Leader move and colour grouping
Cavity options other than connected wires are displayed in as follows.