You will now add a connector to the Fog Lamp Harness.
Fig 36.1 Insert Connector
Click on the Connector command on the toolbar then click on the Harness Node at the end of the bundle. The Create Connector Dialog opens. You can select from a list of connectors which are stored in Component Libraries.
Fig 36.2 Create a Connector Dialog (Search Parts database)
Tip: Acadia is supplied with a sample Component Library. You can create your own Component Libraries containing your own components.
Choose the quickstart library from the drop down menu. Click in the Part Number field.
Click the icon to list all connectors in the library.
Select the 2 Cavity Super Seal Connector Part 0-0282080-1 in the list. Click Populate.
Click Submit. Place the Connector Table on the worksheet. The Connector symbol will automatically place it self in relation to the Connector not obstructing the Bundle, You can then choose to Move the connector if necessary.
The Connector Properties screen opens.
Set the Part Name field to read X-001. Click Submit.
To quick add connectors Right click the node and enter the required Part number, This will automatically search the chosen database for the component, Press Enter to submit.